PON Optical Power Meter

Product Overview

PON  Optical Power Metere

 

Specification

Item Specifications
1310nm upstream measurement
Pass zone (nm) 1260~1360
Isolation @1490/1550nm(dB) >40
MeasurementRange (dBm) -40~+10
1490nm downstream measurement
Pass zone (nm) 1470~1505
Isolation @1550nm(dB) >30
Isolation @1310nm(dB) >40
MeasurementRange (dBm) -40~+10
1550nm downstream measurement
Pass zone (nm)

1535~1570

Isolation @1490nm(dB)

>40

Isolation @1310nm(dB)

>40

MeasurementRange (dBm)

-40~+25

Measurement Accuracy

Connatural Uncertainty (dB)

±0.5

Linearity (dB)

±0.1

Passing through insertion Loss (dB)

<1.5

CW light power measurements

Wavelength(nm)

800~1700nm

MeasurementRange (dBm)

-70~+6 or -50~+26

Uncertainty

±5%

Calibrated Wavelength(nm)

850,1300,1310,1490,1550,1625

Resolution(dB)

0.01

Optical Connector

FC(interchangeable SC,ST)

General Specifications

Display

Graphic display, Resolution is : 128*64

Measurement Unit

dBm, dB and xW

Resolution

0.01dB

Power Supply

1.5V AA Alkaline Batteries (3pcs)

Battery Life

80 hours

Operating Temperature

-10℃ ~ +60℃

Storage Temperature

-25℃ ~ +70℃

Net Weight

550g

Dimensions

210X115X55

VFL Module

Output Power(mW)

1mw

Wavelength(nm)

650

Optical Connector

FC/2.5 universal connector

Working Hours without backlight(Hr)

50